Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Rev Lett ; 126(9): 091101, 2021 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-33750144

RESUMO

We perform a comprehensive study of Milky Way (MW) satellite galaxies to constrain the fundamental properties of dark matter (DM). This analysis fully incorporates inhomogeneities in the spatial distribution and detectability of MW satellites and marginalizes over uncertainties in the mapping between galaxies and DM halos, the properties of the MW system, and the disruption of subhalos by the MW disk. Our results are consistent with the cold, collisionless DM paradigm and yield the strongest cosmological constraints to date on particle models of warm, interacting, and fuzzy dark matter. At 95% confidence, we report limits on (i) the mass of thermal relic warm DM, m_{WDM}>6.5 keV (free-streaming length, λ_{fs}≲10h^{-1} kpc), (ii) the velocity-independent DM-proton scattering cross section, σ_{0}<8.8×10^{-29} cm^{2} for a 100 MeV DM particle mass [DM-proton coupling, c_{p}≲(0.3 GeV)^{-2}], and (iii) the mass of fuzzy DM, m_{ϕ}>2.9×10^{-21} eV (de Broglie wavelength, λ_{dB}≲0.5 kpc). These constraints are complementary to other observational and laboratory constraints on DM properties.

2.
Phys Rev Lett ; 124(10): 101102, 2020 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-32216401

RESUMO

In recent years, many γ-ray sources have been identified, yet the unresolved component hosts valuable information on the faintest emission. In order to extract it, a cross-correlation with gravitational tracers of matter in the Universe has been shown to be a promising tool. We report here the first identification of a cross-correlation signal between γ rays and the distribution of mass in the Universe probed by weak gravitational lensing. We use data from the Dark Energy Survey Y1 weak lensing data and the Fermi Large Area Telescope 9-yr γ-ray data, obtaining a signal-to-noise ratio of 5.3. The signal is mostly localized at small angular scales and high γ-ray energies, with a hint of correlation at extended separation. Blazar emission is likely the origin of the small-scale effect. We investigate implications of the large-scale component in terms of astrophysical sources and particle dark matter emission.

3.
Nucl Instrum Methods Phys Res A ; 702: 88-90, 2013 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-23440608

RESUMO

Silicon based devices can extend PET-MR and SPECT-MR imaging to applications, where their advantages in performance outweigh benefits of high statistical counts.Silicon is in many ways an excellent detector material with numerous advantages, among others: excellent energy and spatial resolution, mature processing technology, large signal to noise ratio, relatively low price, availability, versatility and malleability. The signal in silicon is also immune to effects of magnetic field at the level normally used in MR devices. Tests in fields up to 7 T were performed in a study to determine effects of magnetic field on positron range in a silicon PET device. The curvature of positron tracks in direction perpendicular to the field's orientation shortens the distance between emission and annihilation point of the positron. The effect can be fully appreciated for a rotation of the sample for a fixed field direction, compressing range in all dimensions. A popular Ga-68 source was used showing a factor of 2 improvement in image noise compared to zero field operation. There was also a little increase in noise as the reconstructed resolution varied between 2.5 and 1.5 mm.A speculative applications can be recognized in both emission modalities, SPECT and PET.Compton camera is a subspecies of SPECT, where a silicon based scatter as a MR compatible part could inserted into the MR bore and the secondary detector could operate in less constrained environment away from the magnet. Introducing a Compton camera also relaxes requirements of the radiotracers used, extending the range of conceivable photon energies beyond 140.5 keV of the Tc-99m.In PET, one could exploit the compressed sub-millimeter range of positrons in the magnetic field. To exploit the advantage, detectors with spatial resolution commensurate to the effect must be used with silicon being an excellent candidate. Measurements performed outside of the MR achieving spatial resolution below 1 mm are reported.

4.
Nucl Instrum Methods Phys Res A ; 699(21): 216-220, 2013 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-23230345

RESUMO

Positron emission tomography (PET) is a widely used technique in medical imaging and in studying small animal models of human disease. In the conventional approach, the 511 keV annihilation photons emitted from a patient or small animal are detected by a ring of scintillators such as LYSO read out by arrays of photodetectors. Although this has been a successful in achieving ~5mm FWHM spatial resolution in human studies and ~1mm resolution in dedicated small animal instruments, there is interest in significantly improving these figures. Silicon, although its stopping power is modest for 511 keV photons, offers a number of potential advantages over more conventional approaches. Foremost is its high spatial resolution in 3D: our past studies show that there is little diffculty in localizing 511 keV photon interactions to ~0.3mm. Since spatial resolution and reconstructed image noise trade off in a highly non-linear manner that depends on the PET instrument response, if high spatial resolution is the goal, silicon may outperform standard PET detectors even though it has lower sensitivity to 511 keV photons. To evaluate silicon in a variety of PET "magnifying glass" configurations, an instrument has been constructed that consists of an outer partial-ring of PET scintillation detectors into which various arrangements of silicon detectors can be inserted to emulate dual-ring or imaging probe geometries. Recent results have demonstrated 0.7 mm FWHM resolution using pad detectors having 16×32 arrays of 1.4mm square pads and setups have shown promising results in both small animal and PET imaging probe configurations. Although many challenges remain, silicon has potential to become the PET detector of choice when spatial resolution is the primary consideration.

5.
Phys Rev Lett ; 89(25): 251801, 2002 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-12484873

RESUMO

We report on a search for charmless hadronic B decays to the three-body final states K(0)(S)h(+)pi(-), K(+)h(-)pi(0), K(0)(S)h(+)pi(0) (h(+/-) denotes a charged pion or kaon), and their charge conjugates, using 13.5 fb(-1) of integrated luminosity produced near sqrt[s]=10.6 GeV, and collected with the CLEO detector. We observe the decay B-->K0pi(+)pi(-) with a branching fraction (50(+10)(-9)(stat.)+/-7(syst.))x10(-6) and the decay B-->K(*+)(892)pi(-) with a branching fraction (16(+6)(-5)(stat.)+/-2(syst.))x10(-6).

6.
Phys Rev Lett ; 89(22): 222001, 2002 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-12485061

RESUMO

Using 13.53 fb(-1) of CLEO data, we have measured the ratios of the branching fractions R(+)(e),R(+)(mu) and the combined branching fraction ratio R(+)(l), defined by R(+)(l)=[B(D+-->K(*0)l(+)nu(l))]/[B(D+-->K-pi(+)pi(+))]. We find R(+)(e)=0.74+/-0.04+/-0.05, R(+)(mu)=0.72+/-0.10+/-0.05, and R(+)(l)=0.74+/-0.04+/-0.05, where the first and second errors are statistical and systematic, respectively. The known branching fraction B(D+-->K-pi(+)pi(+)) leads to B(D+-->K(*0)e(+)nu(e))=(6.7+/-0.4+/-0.5+/-0.4)%, B(D+-->K(*0)mu(+)nu(mu))=(6.5+/-0.9+/-0.5+/-0.4)%, and B(D+-->K(*0)l(+)nu(l))=(6.7+/-0.4+/-0.5+/-0.4)%, where the third error is due to the uncertainty in B(D+-->K-pi(+)pi(+)).

7.
Phys Rev Lett ; 89(17): 171803, 2002 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-12398660

RESUMO

Using the CLEO detector at the Cornell Electron Storage Ring we have observed the Omega(0)(c) (css ground state) in the decay Omega(0)(c)-->Omega(-)e(+)nu(e). We find a signal of 11.4+/-3.8(stat) events. The probability that we have observed a background fluctuation is 7.6x10(-5). We measure B(Omega(0)(c)-->Omega(-)e(+)nu(e)).sigma(e(+)e(-)-->Omega(0)(c)X)=(42.2+/-14.1(stat)+/-5.7(syst)) fb and R=[Gamma(Omega(0)(c)-->Omega(-)pi(+))]/[Gamma(Omega(0)(c)-->Omega(-)enu(e))]=00.41+/-0.19(stat)+/-0.04(syst). This is the first statistically significant observation of an individual decay mode of the Omega(0)(c) in e(+)e(-) annihilation and the first example of a baryon decaying via beta emission, where no quarks from the first generation participate in the reaction.

8.
Phys Rev Lett ; 89(28 Pt 1): 282001, 2002 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-12513135

RESUMO

Using the combined CLEO II and CLEO II.V data sets of 9.1 fb(-1) at the Upsilon(4S), we measure properties of psi mesons produced directly from decays of the B meson, where "B" denotes an admixture of B+, B-, B0, and B;(0), and "psi" denotes either J/psi(1S) or psi(2S). We report first measurements of psi polarization in B-->psi(direct)X: alpha(psi(1S))=-0.30(+0.07)(-0.06)+/-0.04 and alpha(psi(2S))=-0.45(+0.22)(-0.19)+/-0.04. We also report improved measurements of the momentum distributions of psi produced directly from B decays, correcting for measurement smearing. Finally, we report measurements of the inclusive branching fraction for B-->psiX and B-->chi(c1)X.

9.
Phys Rev Lett ; 87(25): 251801, 2001 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-11736560

RESUMO

We present the first measurement of the D*(+) width using 9/fb of e(+)e(-) data collected near the Upsilon(4S) resonance by the CLEO II.V detector. Our method uses advanced tracking techniques and a reconstruction method that takes advantage of the small vertical size of the Cornell Electron-positron Storage Ring beam spot to measure the energy release distribution from the D*(+)-->D(0)pi(+) decay. We find gamma(D*(+)) = 96+/-4 (stat)+/-22 (syst) keV. We also measure the energy release in the decay and compute Delta m identical with m(D*(+))-m(D(0)) = 145.412+/-0.002 (stat)+/-0.012 (syst) MeV/c(2).

10.
Phys Rev Lett ; 87(6): 061801, 2001 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-11497821

RESUMO

Using 12.7 fb(-1) of data collected with the CLEO detector at CESR, we observed two-photon production of the cc states chi(c0) and chi(c2) in their decay to pi(+)pi(-)pi(+)pi(-). We measured gamma(gammagamma)(chi(c))xB(chi(c)-->pi(+)pi(-)pi(+)pi(-)) to be 75+/-13(stat)+/-8(syst) eV for the chi(c0) and 6.4+/-1.8(stat)+/-0.8(syst) eV for the chi(c2), implying gamma(gammagamma)(chi(c0)) = 3.76+/-0.65(stat)+/-0.41(syst)+/-1.69(br) keV and gamma(gammagamma)(chi(c2)) = 0.53+/-0.15(stat)+/-0.06(syst)+/-0.22(br) keV. Also, cancellation of dominant experimental and theoretical uncertainties permits a precise comparison of gamma(gammagamma)(chi(c0))/gamma(gammagamma)(chi(c2)), evaluated to be 7.4+/-2.4(stat)+/-0.5(syst)+/-0.9(br), with QCD-based predictions.

11.
Phys Rev Lett ; 87(7): 071802, 2001 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-11497880

RESUMO

We present an observation and time-integrated rate measurement of the decay D(0)-->K(+)pi(-)pi(0) produced in 9 fb(-1) of e(+)e(-) collisions near the Upsilon(4S) resonance. The signal is inconsistent with an upward fluctuation of the background by 4.9 standard deviations. We measured the time-integrated rate of D(0)-->K(+)pi(-)pi(0) normalized to the rate of D(0)-->K(+)pi(-)pi(0) to be 0.0043(+0.0011)(-0.0010) (stat)+/-0.0007 (syst). This decay can be produced by doubly Cabibbo-suppressed decays or by the D(0) evolving into a D(0) through mixing, followed by a Cabibbo-favored decay to K(+)pi(-)pi(0). We also found the CP asymmetry A = (9(+25)(-22))% be consistent with zero.

12.
Phys Rev Lett ; 86(20): 4467-71, 2001 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-11384261

RESUMO

The tau decays to six-pion final states have been studied with the CLEO detector at the Cornell Electron Storage Ring. The measured branching fractions are B(tau(-)-->2pi(-)pi(+)3pi(0)nu(tau)) = (2.2+/-0.3+/-0.4)x10(-4) and B(tau(-)-->3pi(-)2pi(+)pi(0)nu(tau)) = (1.7+/-0.2+/-0.2)x10(-4). A search for substructure in these decays shows that they are saturated by intermediate states with eta or omega mesons. We present the first observation of the decay tau(-)-->2pi(-)pi(+)omega(nu)tau and the branching fraction is measured to be (1.2+/-0.2+/-0.1)x10(-4). The measured branching fractions are in good agreement with the isospin expectations but somewhat below the conserved-vector-current predictions.

13.
Phys Rev Lett ; 86(13): 2732-6, 2001 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-11290026

RESUMO

We report the first observation of exclusive decays of the type B-->D(*)N_NX, where N is a nucleon. Using a sample of 9.7x10(6)B_B pairs collected with the CLEO detector operating at the Cornell Electron Storage Ring, we measure the branching fractions B(B0-->D(*-)p_p pi(+)) = (6.5(+1.3)(-1.2)+/-1.0)x10(-4) and B(B0-->D(*-)p_n) = (14.5(+3.4)(-3.0)+/-2.7)x10(-4). Antineutrons are identified by their annihilation in the CsI electromagnetic calorimeter.

14.
Phys Rev Lett ; 86(7): 1167-70, 2001 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-11178035

RESUMO

Using data recorded with the CLEO II and CLEO II.V detector configurations at the Cornell Electron Storage Rings, we report the first observation and mass measurement of the Sigma(*+)(c) charmed baryon, and an updated measurement of the mass of the Sigma(+)(c) baryon. We find M(Sigma(*+)(c))-M(Lambda(+)(c)) = (231.0+/-1.1+/-2.0) MeV, and M(Sigma(+)(c))-M(Lambda(+)(c)) = (166.4+/-0.2+/-0.3) MeV, where the errors are statistical and systematic, respectively.

15.
Phys Rev Lett ; 86(1): 30-34, 2001 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-11136086

RESUMO

In a sample of 9.66x10(6)B&Bmacr; pairs collected with the CLEO detector we make the first observation of B decays to an eta(c) and a kaon. We measure branching fractions B(B+-->eta(c)K+) = (0.69(+0.26)(-0.21)+/-0.08+/-0.20)x10(-3) and B(B degrees -->eta(c)K degrees ) = (1.09(+0.55)(-0.42)+/-0.12+/-0.31)x10(-3), where the first error is statistical, the second is systematic, and the third is from the eta(c) branching fraction uncertainty. From these we extract the eta(c) decay constant in the factorization approximation, f(eta(c)) = 335+/-75 MeV. We also search for B decays to a chi(c0) and a kaon. No evidence for a signal is found and we set 90% C.L. upper limits: B(B+-->chi(c0)K+)<4.8x10(-4) and B(B degrees -->chi(c0)K degrees )<5.0x10(-4).

16.
Phys Rev Lett ; 87(27 Pt 1): 271801, 2001 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-11800872

RESUMO

We have searched for the two-body decay of the B meson to a light pseudoscalar meson h = pi(+/-),K+/-,K(0)(S) and a massless neutral feebly interacting particle X(0) such as the familon, the Nambu-Goldstone boson associated with a spontaneously broken global family symmetry. We find no significant signal by analyzing a data sample containing 9.7x10(6) BBbar mesons collected with the CLEO detector at the Cornell Electron Storage Ring, and set 90% C.L. upper limits italicB(B(+/-) --> h(+/-)X(0)) = 4.9x10(-5) and italicB(B(0) --> K(0)(S)X(0)) = 5.3x10(-5). These limits correspond to a lower bound of approximately 10(8) GeV on the family symmetry breaking scale with vector coupling involving the third generation of quarks.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...